Doc.nr.:TBKW_17109_A_EN
[1]
BM250 / BM256
Diagnostic Procedure
November 2017
To enter the Diagnostic Mode:
Press and hold the STOP/START button then switch the Power Switch ON
The first screen is an indicator of the software version for development purpose only:
1
st
screen:
1
301
Use the or button to progress through the test
1: motor ON
2: motor OFF
3: heater ON
4: heater OFF
5: motor & heater ON
6: motor & heater OFF
7: buzzer ON
8: buzzer OFF
next LCD display ON – all segments are displayed
next LCD display OFF – display is cleared
The last two screens are internal codes equivalent to temperature readings and are for
development purpose only, for example:
110B
1270
*please note, these codes will change depending on temperature.
The screen will return to:
1
301
and the diagnostic check can be repeated if necessary.
To exit the Diagnostic Mode, press the START/STOP button then switch the Power Switch